Andrew Commscope H5PNF-S Type N Female with Gas Barrier for 7/8" HJ5-50 Air Dielectric Cable

$0.00
Write a Review
SKU:
AND-H5PNF
Availability:
Ships from Manufacturer, Contact us for Pricing and Availability
Adding to cart… The item has been added

Overview

Andrew Commscope H5PNF-S Type N Female with Gas Barrier for 7/8" HJ5-50 Air Dielectric Cable

 

Specifications

General Specifications

Body Style Straight
Cable Family HJ5-50
Gas Barrier Yes
Inner Contact Attachment Method Self-tapping
Inner Contact Plating Silver
Interface N Female
Mounting Angle Straight
Outer Contact Attachment Method Tab-flare
Outer Contact Plating Silver

Dimensions

Length 72.898 mm | 2.87 in
Diameter 41.402 mm | 1.63 in
Nominal Size 7/8 in

Electrical Specifications

Insertion Loss, typical 0.05 dB
Average Power at Frequency 0.6 kW @ 900 MHz
Cable Impedance 50 ohm
Connector Impedance 50 ohm
dc Test Voltage 2 kV
Insulation Resistance, minimum 5000 mOhm
Operating Frequency Band 0 – 5200 MHz
Peak Power, maximum 10 kW
RF Operating Voltage, maximum (vrms) 707 V

Return Loss/VSWR

Frequency Band VSWR Return Loss (dB)
0–1000 MHz 1.020 40.09
1–2200 MHz 1.030 36.61
2200–4000 MHz 1.080 28.30
4000–5200 MHz 1.150 23.13

Mechanical Specifications

Mechanical Shock Test Method MIL-STD-202, Method 213, Test Condition I

Environmental Specifications

Operating Temperature -40 °C to +85 °C (-40 °F to +185 °F)
Storage Temperature -70 °C to +85 °C (-94 °F to +185 °F)
Corrosion Test Method MIL-STD-202, Method 101, Test Condition B
Moisture Resistance Test Method MIL-STD-202, Method 106
Thermal Shock Test Method MIL-STD-202, Method 107, Test Condition A-1, Low Temperature -55 °C
Vibration Test Method MIL-STD-202, Method 204, Test Condition B

Packaging and Weights

Weight, net 0.35 kg | 0.772 lb