Overview
Andrew Commscope AL5E78-PS 7/8" EIA Positive Stop for AVA5
Specifications
Product Classification
| Product Type | Wireless and radiating connector |
| Product Brand | HELIAX® | Positive Stop™ |
| Product Series | AVA5-50 | AVA5RK-50 |
General Specifications
| Body Style | Straight |
| Cable Family | AL5-50 | AVA5-50 |
| Inner Contact Attachment Method | Captivated |
| Inner Contact Plating | Silver |
| Interface | 7/8 in EIA Flange |
| Mounting Angle | Straight |
| Outer Contact Attachment Method | Ring-flare |
| Outer Contact Plating | Trimetal |
| Pressurizable | No |
Dimensions
| Length | 88.65 mm | 3.490 in |
| Diameter | 57.15 mm | 2.250 in |
| Nominal Size | 7/8 in |
Electrical Specifications
| 3rd Order IMD at Frequency | -116 dBm @ 910 MHz |
| 3rd Order IMD Test Method | Two +43 dBm carriers |
| Insertion Loss, typical | 0.05 dB |
| Average Power at Frequency | 2.3 kW @ 900 MHz |
| Cable Impedance | 50 ohm |
| Connector Impedance | 50 ohm |
| dc Test Voltage | 6000 V |
| Inner Contact Resistance, maximum | 1.5 mOhm |
| Insulation Resistance, minimum | 5000 mOhm |
| Operating Frequency Band | 0 – 5000 MHz |
| Outer Contact Resistance, maximum | 1.5 mOhm |
| Peak Power, maximum | 90 kW |
| RF Operating Voltage, maximum (vrms) | 2120 V |
| Shielding Effectiveness | -130 dB |
Return Loss/VSWR
| Frequency Band | VSWR | Return Loss (dB) |
| 50–1000 MHz | 1.036 | 35.05 |
| 1700–2200 MHz | 1.036 | 35.05 |
| 2400–2700 MHz | 1.065 | 30.04 |
| 3400–3600 MHz | 1.119 | 25.01 |
Mechanical Specifications
| Attachment Durability | 25 cycles |
| Connector Retention Tensile Force | 1334.47 N | 300.000 lbf |
| Connector Retention Torque | 8.1 N-m | 71.691 in lb |
| Coupling Nut Proof Torque | 24.86 N-m | 220.003 in lb |
| Insertion Force | 66.72 N | 15.000 lbf |
| Insertion Force Method | IEC 61169-1:15.2.4 |
| Interface Durability | 50 cycles |
| Mechanical Shock Test Method | MIL-STD-202, Method 213, Test Condition I |
Environmental Specifications
| Operating Temperature | -55 °C to +85 °C (-67 °F to +185 °F) |
| Storage Temperature | -55 °C to +85 °C (-67 °F to +185 °F) |
| Attenuation, Ambient Temperature | 20 °C | 68 °F |
| Average Power, Ambient Temperature | 40 °C | 104 °F |
| Corrosion Test Method | MIL-STD-1344A, Method 1001.1, Test Condition A |
| Immersion Depth | 1 m |
| Immersion Test Mating | Unmated |
| Immersion Test Method | IEC 60529:2001, IP68 |
| Moisture Resistance Test Method | MIL-STD-202F, Method 106F |
| Thermal Shock Test Method | MIL-STD-202F, Method 107G, Test Condition A-1, Low Temperature -55 °C |
| Vibration Test Method | MIL-STD-202F, Method 204D, Test Condition B |
| Water Jetting Test Mating | Unmated |
| Water Jetting Test Method | IEC 60529:2001, IP66 |
Packaging and Weights
| Weight, net | 340.21 g | 0.75 lb |