Overview
BDI SWP-200 RF Switch Controller with DPS-100D Power Monitor is suitable for digital and analog forward- and reflected-power measurements. The SWP-200 provides complete control of one to up to four RF switches. The SWP-200 can be interfaced to most four port switches and optionally can be provided with interface cables for most four port switches made. The SWP-200 provides one-button control of four port switches, manages interlock closures and transmitter control in a single rack unit chassis. Optional features include RF failure and RF safety sensing to protect a switch from damage if RF is present and a switch command is called for. The SWP-200 can operate in hands-off, pre-programmed mode, or in manually controlled mode. The SWP-200 also can be used in AM radio applications to control multiple open frame contactors. This is a versatile RF support product that provides around-the-clock peace of mind!
Models Available
BDI Model # | SWP-200 Switch Controller & Couplers Included | SENSOR TYPE SUPPLIED |
SWP-200-1R1- N | RF+CTL 1-SWITCH + TYPE N COUPLER | 1-DPS-100D |
SWP-200-1R1- 7/8 | RF+CTL 1-SWITCH + 7/8 COUPLER | 1-DPS-100D |
SWP-200-1R1-7/16 | RF+ CTL 1-SWITCH + 7/16 DIN COUPLER | 1-DPS-100D |
SWP-200-1R1-1 5/8 | RF+CTL 1-SWITCH + 1-5/8 COUPLER | 1-DPS-100D |
SWP-200-1R1-3 1/8 | RF+CTL 1-SWITCH + 3-1/8 COUPLER | 1-DPS-100D |
SWP-200-1R2-N | RF+CTL 1-SWITCH + 2 - TYPE N COUPLERS | 2-DPS-100D |
SWP-200-1R2-7/8 | RF+CTL 1-SWITCH + 2 - 7/8 COUPLERS | 2-DPS-100D |
SWP-200-1R2-7/16 | RF+CTL 1-SWITCH + 2 - 7 /16 DIN COUPLERS | 2-DPS-100D |
SWP-200-1R2-1-5/8 | RF+CTL 1-SWITCH + 2 - 1-5/8" COUPLERS | 2-DPS-100D |
SWP-200-1R2-3-1/8 | RF+CTL 1-SWITCH + 2 - 3-1/8" COUPLERS | 2-DPS-100D |
4 1/16", 6 1/8" Models Available, Please contact us.
Specifications
DSP-100D Power Monitor
- Electrical Specifications: Frequency Range: Sensor: 0.5 MHz—4GHz—Model Dependent
- Through Line VSWR: 1.05:1 or better Coupled Port
- Directivity: 30 dB or better
- Impedance: 50 ohms through port
- Measurement Type: True RMS – Suitable for CW, multi carrier and high crest factor digital RF signals such as AM/FM, 8 VSB (ATSC 1.0/3.0 ), DVB-T, ISDB-T,DTMB, IDRM, IBOC (in band on channel Ibiquity standard). DAB, etc.
- Accuracy: +/- 5% of indicated reading maximum error within instrument dynamic range.
- Dynamic Range: 40db or better Linear dynamic Range.
- Power Measurement Range 0 – 2.5 Mega watt Model and Coupler Line Size Dependent
- Measurement Capabilities: Forward and Reflected RF Power, Transmission line temperature (Deg F / Deg C user selectable) 1 each – External Temperature and line pressure sensors. 6 – User configurable closure inputs. (typically patch panels, lock-out/tag-out) Integrated Digital Display: 2 Line x 16 character LCD display of Fwd/Ref RF Power, Temperature (x2), Line Pressure Dedicated Icons for VSWR fault, Alert Status, Communications Status, RF Power High/Low thresholds, DC power input status and LAN connection status.
- Communications Interfaces: Ethernet, RS-485, Network Protocols: SNMP, SMTP, TCP/IP, UDP, SNTP, 2 – Configurable VDC proportional power outputs, 2 – Form C configurable interlock/status relays/On/off 2 – Configurable External GP inputs for fault reset 12 Position Termi nal Block: 6 – Configurable General Purpose Inputs for lock out tag out, patch panel, external interlock strings, etc. Ext. Temperature Sensor Input3 – Position terminal block mates with BDI TMP-100 T
- Physical Specifications:
Sizes: N, DIN, 7/8” 1-5/8”, 3-1/8” EIA, 4-1/16” Myat standard, 4-1/16” Dielectric standard, 6-1/8”, 9” and 12” special order. Flanged – One fixed, one swivel - Environmental Specifications:
Operating Temperature: ‐25°C to +55°C
Storage Temperature: ‐60°C to +85°C
Humidity: 95% Non‐Condensing
SWP-200 Controller
- Modes Supported: TX1/TX2 select to Air—SWP‐200‐1T, ANT1/ANT2 select, TX1/TX2 select to Air—SWP‐200‐2T,
- Number of Switches Supported: SWP‐200‐1T—1, SWP‐200‐2T—2
- Switch Control Voltage: 12 or 24 VDC
- Switch Manufactures supported: Dasto, Delta, Dielectric, DowKey, ERI, MCI, Myat, Spinner
- TransmiƩer and Interlock Control: Both models control up to two transmiƩers providing TX ON/OFF and Interlock Management
- TransmiƩer Interface: Form C dry contact relays
- Remote Control interface SWP‐200‐1T: General Purpose I/O Control of Air Selected transmiter ON/OFF, Motorized Switch PosiƟon, Switch positon of second switch—SWP‐200‐2T Model, Fault Reset*
- Additional Remote Control interface functons for SWP‐200‐2T: Antenna 1/2 Command/Status, Antenna Auto/Manual Command/Status,
- Status Available: Motorized Switch positon, Fault Status, TX1,2 Interlock, Air TransmiƩer ON/OFF
- AC Power Loss Monitor: Monitors for presence of AC Power loss to transmiƩer(s) to prevent switch operaƟon in auto mode if AC power is lost to transmiƩers—Logic input requires external circuitry
- Power Measurement Range: 10 Watt to 100 KW Full Scale Indicaton*
- Power Measurement Accuracy: +/‐5% of Reading—Dynamic Range 40 below Full Scale Indicaton*
- Communicatons Interface: RS232/485, TCP/IP— Ethernet TCP/IP, SNMPv2 Agent and BDI Graphical User Interface CompaƟble with Windows XP, 7 , 8 ,10, Android
- Physical Dimensions: 19” W X 10”D X 1.75” H—EIA Standard 1 Rack Unit
- Electrical Requirements: 100‐240 VAC 50/60 Hertz @ 0.5 ampere
- Environmental: 0‐60 degrees C, non condensing atmosphere
* ‐ SWP‐2001/2R1‐1T/2T versions which include DPS‐100D Power Meter/Line SecƟon. Maximum Power Measurement is line size dependent. See ordering informaƟon for models available.