RVR TEX100LCD/S 100 Watt Transmitter

$0.00
Write a Review
SKU:
RVR-TEX100LCDS
Availability:
Ships from Manufacturer, Contact us for Pricing and Availability
Adding to cart… The item has been added

Overview

RVR TEX100LCD/S 100 Watt Transmitter

  • PRIMARY APPLICATION: high quality at a very attractive price.Ideal for use as exciters in compact and modular system.
  • HARDWARE FEATURES: compact, non-deformable and light thanks to the stainless steel chassis, in 2 rack units only.
  • USER-FRIENDLY FEATURES: universal 80-260 V multi-voltage power supply enables operation without preselect voltage. Four pushbuttons for user/device interaction and software that offers a simple, intuitive interface.
  • RELIABILITY/CONTINUITY: APC (Automatic Power Control) and Foldback protection ensure reliable operation under any operating conditions.
  • AUDIO PERFORMANCE: low distortion and intermodulation values and a high noise/signal ratio.
  • OPERATING EFFICIENCY: incorporate a PFC (Power Factor Corrector) power supply, that provides the utmost efficiency for enhanced energy saving and environmental protection, which ensure high efficiency across the bandwidth.
  • EASE OF MAINTENANCE: advanced module engineering ensures extreme of access and simple maintenance.
  • INTERFACE CONTROL: total control thanks to microprocessor easily programmed from menu with all key parameters displayed on LCD.
  • INPUT/OUTPUT INTERFACE: built-in high-performance stereo coder, L&R analogue audio inputs, Mono inputs, MPX composite signal and auxiliary inputs for SCA / RDS signals.
  • RDS APPLICATION: built-in RDS encoder with UECP standard functions (option).
  • REMOTE CONTROL: built-in telemetry system via GSM modem, battery and battery charger or via WEB or via SNMP (option).
  • REGULATORY COMPLIANCE: state-of-the-art technology in full compliance with EC, FCC and CCIR standards.

Specifications

TEX100LCD/S
Parameters   U.M. Value Notes
GENERALS        
Frequency range   MHz 87,5 ÷ 108  
Rated output power   W 100 Continuously adjustable from 10 to 100%
Modulation type     F3E Direct carrier frequency  
Operational mode     Mono, Stereo, Multiplex  
Working temperature   °C -5 to +50  
Working humidity   % 95 No condensing
Working altitude   mt Up to 3000 * * With adequate air evacuation system in site
Frequency setting    kHz 10  Steps
Frequency stability Temperature range from -5°C to 50°C ppm ±1  
Modulation capability Refered @ 0dBu for 75kHz kHz 150 Stereo, 180 Mono/MPX Meets or exceeds all FCC and CCIR rules
Pre-emphasis   µS 0, 50 (CCIR), 75 (FCC) Selectable
POWER REQUIREMENTS        
AC Power input AC Supply Voltage VAC 115 / 230 ±15%  Internal switch 
  AC Apparent Power Consumption VA 330  
  Active Power Consumption  W 212  
  Power Factor   0,6  
  Overall Efficiency % Typical 47  
  Connector   VDE IEC Standard  
MECHANICAL DIMENSIONS        
Phisical dimensions Front panel width mm / inch 483  /  19 EIA rack
  Front panel height mm / inch 88  /  3 1/2 2HE
  Overall depth mm 394  
  Chassis depth mm 372  
Weight   kg About 8,5  
Cooling     Forced, with internal fan  
Acoustic noise   dBA < 58  
AUDIO INPUTS        
Left / Mono Connector   XLR F  
  Type   Balanced   
  Impedance Ohm 10 k or 600  
  Input Level /Adjust dBu -13 to +13 Continuosly adjustable
Right Connector   XLR F  
  Type   Balanced   
  Impedance Ohm 10 k or 600  
  Input Level dBu -13 to +13 Continuosly adjustable
MPX Connector   BNC  
  Type   Unbalanced  
  Impedance Ohm 10 k or 50  
  Input Level /Adjust dBu -13 to +13 For 75 KHz FM, adjustable
SCA/RDS Connector   2xBNC  
  Type   Unbalanced  
  Impedance Ohm 10 k   
  Subcarier Level @ 0 dBu dB -17 to -40 For 7,5 KHz FM, adjustable
AES/EBU (optional) Connector   XLR F  
  Type   Balanced  
  Impedance Ohm 110  
  Input Level /Adjust dBfs 0 to -10 For 7,5 KHz FM, adjustable
TOS/Link
(optional)
    TOS-Link  
      Optical  
OUTPUTS         
RF Output Connector   N type  
  Impedance Ohm 50  
RF Monitor Connector   BNC  
  Impedance Ohm 50  
  Output Level dB Approx. -60  
Pilot output Connector   BNC  
  Load Impedance Ohm >5 K  
  Output Level Vpp 1 Sinusoidal
FUSES        
On mains     1 External fuse F 6,3 T - 5x20 mm  
On services     X  
On PA Supply     X  
On driver supply     X