RDL HD-MA35A 35W Mixer Amp - 25V, 70V or 100V

MSRP: $533.70
$400.27
Write a Review
SKU:
RDL-HDMA35A
Availability:
Ships from Manufacturer, Contact us for Pricing and Availability
Type:
Power Amplifier

Overview

The HD-MA35A is a three input audio mixer amplifier for systems demanding a broad range of features and high energy efficiency. Two output power amplifier zones are provided, 35 W (Zone 1) and 2 W (Zone 2). The Zone 1 output is driven from a high-efficiency Class D amplifier stage. The Zone 1 amplifier output level may be VCA controlled using various optional RDL remote controls, or by industry standard 0 to 10 Vdc or 0 to 10 kOhm controls. This output provides a constant voltage (25 V, 70 V or 100 V). The Zone 2 amplifier output drives an 8 Ohm speaker and/or 600 Ohm telephone equipment. The HD-MA35A is engineered and manufactured in the U.S.A.

The HD-MA35A features two mixers. The Zone 1 mixer is located on the front-panel providing user level and tone controls for the 35 W amplifier output. The tone controls adjust the equalization at the Zone 1 amplifier output. The Zone 2 mixer on the rear panel provides level trimmers normally set by the installer to provide music-on-hold and/or for background music in a small zone equipped with an 8 Ohm speaker. The Zone 2 section includes a 2 W amplifier and a 600 Ohm transformer-balanced MOH output.

The HD-MA35A has three inputs that are common to both mixers. Input 1 accepts a balanced mic or line level source. Inputs 2 and 3 accept unbalanced mono or stereo line-level sources.

 

  • Input 1 is switch-selectable MIC or LINE. Phantom voltage (IEC standard 24 Vdc) is switch-selectable for the microphone input. The line input is transformer isolated and accepts balanced or unbalanced, high or low impedance audio sources.
  • A paging source is normally connected to Input 1. This input is equipped with push-to-talk terminals and with an adjustable threshold VOX circuit with LED threshold indicator, either (or both) of which may be set to duck ("fade down" or "mute") inputs 2 and/or 3 by 25 dB when a paging signal is active on Input 1. The attenuated inputs fade up to normal volume when the paging message is finished.
  • Inputs 2 and 3 each provide unbalanced stereo RCA input jacks, summed to mono.

 

The HD-MA35A is equipped with a master VCA for remote adjustment of the Zone 1 amplifier output. A detachable terminal block is provided for direct connection of an optional RDL remote level control.

A balanced line-level output is provided on a detachable terminal block to feed the inputs of other audio equipment or power amplifiers. Ground-referenced 24 Vdc power is available on a rear-panel terminal block to power an optional external RDL module which may be mounted on the panel space provided. External module type examples: audio filtering or processing, mixing, isolation, twisted-pair sender/receiver.

The Zone 1 amplifier includes an analog compressor/limiter for audio fidelity noticeably superior to conventional class D amplifiers with digital limiting. Increasing the input gain can substantially increase the average output power beyond that of a standard 35 W amplifier. A red front-panel LED flashes when the compressor is preventing output clipping. Normal audio level signals remain unaffected by the compressor thereby preserving audio dynamics. The audio is compressed according to three dynamic time constants providing aural transparency while maintaining clean, unclipped amplified audio for input overloads of up to 20 dB. The HD-MA35A, with compression, is capable of producing average audio output levels and clarity normally expected from amplifiers with a much higher output power rating.

A blue POWER LED illuminates when the HD-MA35A is powered from its external 24 Vdc power supply (included). The power LED is dim when the mixer amplifier is in the standby mode, and is bright when the amplifiers are fully active. A front-panel pushbutton is provided to manually switch between standby and active modes. The power amplifiers are equipped with both thermal and output short-circuit protection. The high-efficiency Class D output stage produces minimal heat for all levels of expected voice or music modulation.

Features:

  • Three inputs with individual front-panel volume controls
  • Bass and Treble tone controls
  • Designed for background music with paging and music-on-hold
  • Master volume VCA controlled with remote adjustment capability
  • Manual or automatic (VOX) priority ducking
  • Balanced inputs and amplified outputs on detachable terminal blocks
  • Unbalanced inputs and outputs on RCA jacks
  • Includes power supply
  • High-efficiency Class D operation

 

Specifications

Amplifier Zones (2):
 
Zone 1 (Main): 35 W RMS, front-panel mixer (user controls); Zone 2: 2 W RMS (8 Ohms), rear-panel mixer (trimmers)

Audio Inputs (3):
 
Balanced, mic or line switch selectable on terminal block; 2, unbalanced stereo summing inputs on RCA jacks

Maximum Input Level:
 
Mic Input: -11.5 dBu; Balanced line input: + 19 dBu; Unbalanced Inputs: + 9 dBV (+15.5 dBV, one input); (for 1% THD+N at output)

Phantom Voltage:
 
24 Vdc (IEC 61938: 2013), switch-selectable for the mic input

Ducking/Muting Actuation:
 
Automatic (Input 1 VOX: rear-panel adjustable signal threshold with LED indicator) or Manual (contact closure to ground)

Ducking/Muting Release Delay:
 
4 seconds, nominal

Ducking/Muting:
 
Switch-selectable for inputs 2 and/or 3, 25 dB ducking attenuation, nominal

External RDL Module Power Output:
 
24 Vdc, 100 mA maximum, ground-referenced

Input level:
 
(to cross compressor threshold equaling 23 W amplified output)
Mic Input: -50 dBu (2.5 mV), (front panel gain at max.)
Balanced line input: -21 dBu (70 mV), (front panel gain at max.)
Unbalanced Inputs: -15 dBV (180 mV, front panel gain at max., both inputs driven)

Noise (line output):
 
Mic input: -68 dB, Balanced line input: -72 dB (below compressor threshold at max gain);
Unbalanced Inputs: <-85 dB (max gain)

Noise (amplified outputs):
 
Mic input: -68 dB, Balanced line input: -72 dB (below compressor threshold at max gain);
Unbalanced Inputs: <-75 dB (max gain)

THD+N:
 
< 0.5% (1 kHz at compressor threshold, main amp output); < 0.25% (line output, main)

CMRR: Mic input:
 
> 50 dB (50 Hz to 120 Hz); Balanced line input: > 80 dB (50 Hz to 120 Hz, transformer-coupled input)

Compressor:
 
Threshold 2 dB below rated output, automatically adjusting attack and release times

Frequency Response (mixer):
 
Mic to line output: ±1.5 dB (40 Hz to 25 kHz); Balanced line input to line output: ±1 dB (20 Hz to 20 kHz); Unbalanced line input to line output: ±0.5 dB (20 Hz to 20 kHz)

Frequency Response (Zone 1 amplifier):
 
Constant voltage: ±3 dB (50 Hz to 18 kHz); 4/8 Ohm: ±1 dB (50 Hz to 20 kHz)

Frequency Response (Zone 2 amplifier):
 
8 Ohm: ±1.5 dB (50 Hz to 20 kHz); 600 Ohm: ±1.5 dB (30 Hz to 18 kHz)

Tone Controls:
 
±10 dB @ 10 kHz, ±9 dB @ 100 Hz (front-panel) with center detent

Audio Outputs (2):
 
+4 dBu nominal (1.23 V), balanced, terminal block (FLAT); 0 dBu nominal balanced, terminal block (zone 2 mixer, 600 Ohm output)

MOH Output:
 
0 dBu nominal (775 mV), 600 Ohm transformer-isolated, >16 dB headroom

Power Amplifier Outputs (2):
 
Zone 1 (main): 35 W RMS (25, 70 or 100 V); Zone 2: 2 W (8 Ohms, on detachable terminal block)

Indicators (6):
 
Front-panel: Signal present (3; 1 per input, green), Compressor activity (red), Power (bright=on, dim=standby, blue); Rear-panel: Ducking/muting threshold (yellow)

VCA:
 
Zone 1 (main) master level, 0 to 10 Vdc control, detachable terminal block (compatible with RDL VCA wall controls)

Front-panel controls (6):
 
Zone 1 (main) mixer level controls (3, inputs 1 through 3), EQ (2, bass and treble), Power (latching pushbutton, on/standby)

Rear-panel controls (9):
 
Mic/Line switch (Input 1), Input 1 ducking/muting detector sensitivity trimmer, Phantom voltage switch (Input 1), Ducking control switches (2, to duck inputs 2 and/or 3), Zone 2 mixer level controls (3, inputs 1 through 3), HD-MA35: Output impedance switch 4 or 8 Ohms

Ambient Operating Environment:
 
0° C to 50° C Maximum; 20° C Recommended

Power Supply (included):
 
100 to 240 Vac, 50-60 Hz, 50 W; 24 Vdc output to amplifier chassis

Dimensions and Weight:
 
Height: 3.5 in.(8.89 cm); Width: 8.5 in.(21.6 cm); Depth: 6.75 in.(17.1 cm); Weight: 6 lb.(2.7 kg)

Package Type:
 
Cardboard Box

Package Dimensions:
 
10.75 x 9.125 x 3.9375 in.

Shipping Weight:
 
7.095 lbs.

WEEE weight:
 
5.975 lbs.

Tariff code:
 
8518.50.0000

 

RDL Three-Year Limited Warranty Installation of these products by the Purchaser shall constitute Purchaser’s acknowledgement and acceptance of the terms and conditions for sale and of this warranty, and shall constitute the Purchaser’s determination of the suitability of this product for the Purchaser’s intended application. Radio Design Labs, Inc., also referred to as RDL®, warrants to the Purchaser that products manufactured by RDL are free from defects in material and workmanship. This warranty applies to the period of three years from the date of shipment, except for component parts or products purchased from other sources and supplied by RDL. Such component parts or products bear only the warranty of the manufacturer thereof in effect at the time of shipment to the Purchaser. RDL will, without charge, and after written notice has been received and acknowledged by RDL, repair an RDL product if proved to be defective according to the usage of the trade, when such equipment is received by RDL at the location it designates with shipment costs prepaid by the Purchaser. RDL shall not be liable for any expense whether for repairs, replacements, material, service, or otherwise, incurred by the Purchaser or modifications made by the Purchaser to the product. No equipment shall be deemed defective if it shall fail to operate in a normal or proper manner due to exposure to excessive moisture in the atmosphere, excessive temperature extremes, improper environmental cleanliness, or any other environment not consistent with the principles of good engineering practice. In no event shall RDL have any liability for consequential damage or expense directly or indirectly arising from the use of the products, or any inability to use it either separately or in combination with other equipment or materials, or from any other cause, whether used in accordance with instructions or not. This warranty is void if equipment is altered in any way by other than RDL. RDL products are NOT intended for use in life support appliances, devices, or systems. Use of RDL products in such applications is done solely at the liability of the reseller/installer and/or end user. RDL reserves the right to change design parameters and specifications at any time without notice. The performance measurements reflect the products at the time of printing. This warranty is in lieu of all others, either expressed or implied. No representative is authorized to assume for RDL any other liability in connection with RDL products.