Overview

The DB-SH1 is used in applications requiring headphones of any impedance to be driven from consumer or professional audio sources. The DB-SH1 is ideally suited to applications as diverse as language translation, museums, interview studios and music stores. The module mounts conveniently in a precut opening in a wood or metal enclosure or in various RDL mounting accessories. The DB-SH1 is a dual channel headphone amplifier with balanced/unbalanced left and right inputs. Each input accepts operating levels between -20 dBV and +20 dBu. Two recessed slide switches located on the side of the rear enclosure are set prior to mounting the module. One switch is provided for setting the input sensitivity. The mode switch selects between stereo and mono operation. In the mono position, the left input is used to drive both output channels. When the module is used in a monaural system, only the left channel input must be wired. The front panel level control is a long life potentiometer controlling matched VCAs. Audio does not pass through this control, assuring years of noise free level adjustment. The output amplifiers deliver more than 50 mW into either high or low impedance headphones through a durable, metal ¼" (6.3 mm) standard headphone jack. Module operation is from a 24 Vdc ground referenced power supply. It can also operate from a 12 Vdc supply with a 6 dB reduction in headroom and a maximum output power of 10 mW.

Features:

  • Panel-Mounted Headphone Amplifier
  • Wall-Mounted Headphone Amplifier
  • Integral Long-Life VCA Stereo Level Control
  • Balanced or Unbalanced Inputs
  • Switch-Selectable Input Sensitivity
  • Switch-Selectable Mono (Left) or Stereo Operation
  • Amplifier To Drive High or Low Impedance Headsets
  • Convenience of Decora® Mounting Possibilities

Specifications

Inputs (2):
 
10 kΩ balanced or unbalanced bridging

Input Level:
 
+4 dBu nominal (Low input sensitivity);
-15 dBV nominal (High input sensitivity)

Maximum Input Level:
 
+21 dBu (Low input sensitivity);
+3 dBu (High input sensitivity)

Output Signal (normal rated):
 
10 mW into 100 Ω

Output Signal (maximum):
 
50 mW into 100 Ω

THD+N:
 
< 0.5% @ 1 kHz

Frequency Response:
 
30 Hz to 20 kHz (± 2 dB)

Noise:
 
< -70 dB below normal operating level

Gain:
 
User-adjustable on front panel 18.5 dB (maximum, High input sensitivity); Unity (maximum, Low input sensitivity)

CMRR:
 
> 60 dB (50 to 120 Hz)

Crosstalk:
 
Below noise floor (20 Hz to 20 kHz)

Ambient Operating Environment:
 
0° C to 55° C

Power Requirement:
 
GROUND-REFERENCED 24 Vdc @ 50 mA

Package Type:
 
Cardboard Box

Package Dimensions:
 
3.625 x 4.625 x 2.125 in.

Shipping Weight:
 
0.475 lbs.

WEEE weight:
 
0.325 lbs.

Tariff code:
 
8543.70.9960

 

RDL Three-Year Limited Warranty Installation of these products by the Purchaser shall constitute Purchaser’s acknowledgement and acceptance of the terms and conditions for sale and of this warranty, and shall constitute the Purchaser’s determination of the suitability of this product for the Purchaser’s intended application. Radio Design Labs, Inc., also referred to as RDL®, warrants to the Purchaser that products manufactured by RDL are free from defects in material and workmanship. This warranty applies to the period of three years from the date of shipment, except for component parts or products purchased from other sources and supplied by RDL. Such component parts or products bear only the warranty of the manufacturer thereof in effect at the time of shipment to the Purchaser. RDL will, without charge, and after written notice has been received and acknowledged by RDL, repair an RDL product if proved to be defective according to the usage of the trade, when such equipment is received by RDL at the location it designates with shipment costs prepaid by the Purchaser. RDL shall not be liable for any expense whether for repairs, replacements, material, service, or otherwise, incurred by the Purchaser or modifications made by the Purchaser to the product. No equipment shall be deemed defective if it shall fail to operate in a normal or proper manner due to exposure to excessive moisture in the atmosphere, excessive temperature extremes, improper environmental cleanliness, or any other environment not consistent with the principles of good engineering practice. In no event shall RDL have any liability for consequential damage or expense directly or indirectly arising from the use of the products, or any inability to use it either separately or in combination with other equipment or materials, or from any other cause, whether used in accordance with instructions or not. This warranty is void if equipment is altered in any way by other than RDL. RDL products are NOT intended for use in life support appliances, devices, or systems. Use of RDL products in such applications is done solely at the liability of the reseller/installer and/or end user. RDL reserves the right to change design parameters and specifications at any time without notice. The performance measurements reflect the products at the time of printing. This warranty is in lieu of all others, either expressed or implied. No representative is authorized to assume for RDL any other liability in connection with RDL products.