Overview
RFS Cablewave LCF12-50J 1/2" CELLFLEX® Low-Loss Foam-Dielectric Coaxial Cable
- Ultra Low Attenuation
The reduced attenuation of CELLFLEX® coaxial cable results in extremly efficient signal transfer in your RF system, especially at high frequencies. - Complete Shielding
The solid outer conductor of CELLFLEX® coaxial cable creates a continuous RFI/EMI shield that minimizes system interference. - Low VSWR
Special low VSWR versions of CELLFLEX® coaxial cables contribute to low system noise. - Outstanding Intermodulation Performance
CELLFLEX® coaxial cable's solid inner and outer conductors virtually eliminate intermods. Intermodulation performance is also confirmed with state-of-the-art equipment at the RFS Technologies factory. - High Power Rating
Due to their low attenuation, outstanding heat transfer properties and temperature stabilized dielectric materials, CELLFLEX® cable provides safe long term operating life at high transmit power levels. - Wide Range of Application
Typical areas of application are: feedlines for broadcast and terrestrial microwave antennas, wireless cellular, PCS and ESMR base stations, cabling of antenna arrays, and radio equipment interconnects
Specifications / Documents
Structure
- Size: 1/2
- Inner Conductor mm (in): 4.8 (0.189)
- Inner Conductor Material: Copper-Clad Aluminum Wire
- Dielectric: mm (in) 11.3 (0.445)
- Dielectric Material: Foam Polyethylene
- Outer Conductor: mm (in) 13.8 (0.543)
- Outer Conductor Material: Corrugated Copper
- Jacket: mm (in) 15.8 (0.622)
- Jacket Material Black Polyethylene
TESTING AND ENVIRONMENTAL
- Compliance
- DIN EN ISO 9001:2015
- ISO 14001:2015
- RoHS 2011/65/EU - China RoHS SJ/T 11364-2006
- REACH (EC 1907/2006)
- UL1581 - UV Resistance Jacket
- IEC 60754-1/-2
- Installation Temperature: °C(°F) -40 to 60 (-40 to 140)
- Storage Temperature: °C (°F) -70 to 85 (-94 to 185)
- Operation Temperature: °C(°F) -50 to 85 (-58 to 185)
ELECTRICAL SPECIFICATIONS
- Impedance: Ω 50 +/- 1
- Maximum Frequency: GHz 8.8
- Velocity: % 87
- Capacitance: pF/m (pF/ft) 76 (23.2)
- Inductance: uH/m (uH/ft) 0.19 (0.058)
- Peak Power Rating: kW 38
- RF Peak Voltage: Volts 1950
- Jacket Spark Volt: RMS 8000
- Inner Conductor dc Resistance
- Ω/1000 m 1.62
- Ω/1000 ft .05
- Outer Conductor dc Resistance
- Ω/1000 m 3.55
- Ω/1000 ft 1.08
- Return Loss (VSWR) Performance
- 20 (1.22) @ 450-617 MHz
- 24 (1.13) @ 617-960 MHz
- 24 (1.13) @ 1695-2200 MHz
- 20 (1.22) @ 2300-2700 MHz
- 18 (1.28) @ 3500-4200 MHz
- 16 (1.37) @ 5150-6000 MHz
MECHANICAL SPECIFICATIONS
- Cable Weight, Nominal: kg/m (lb/ft) 0.18 (0.125)
- Minimum Bending Radius, Single Bend: mm (in) 70 (2.756)
- Minimum Bending Radius, Repeated Bends: mm (in) 125 (4.921)
- Bending Moment: Nm (lb-ft) 6.5 (4.79)
- Tensile Strength N (lb) 1050 (236)
- Recommended / Maximum Clamp Spacing: m (ft) 0.6 / 1 (2 / 3.25)
|