Overview
The RU-SM16A is the ideal choice in most applications where audio level metering is to be designed into a system or added to existing equipment. The RU-SM16A has two separate inputs. Each input may be individually calibrated for unbalanced consumer, balanced professional, 8 Ohm speaker line or constant voltage speaker lines (25 V, 70 V or 100 V). All connections are made using detachable terminal blocks.
A rear-panel switch selects variable or fixed calibration for 25V, 70V, 100V and +4 dBu sources. In the "variable" position, front-panel multi-turn trimmers adjust the calibrated meter levels.
Rear-panel switches allow the installer to set each meter individually for either peak or average audio level display. In stereo applications, either peak or average is typically selected. In monaural installations, it may be advantageous to feed the mono source to both meters, setting one for peak and the other for average. In either mode the upper three LEDs (+10, +14, +18) remain in the PEAK HOLD mode.
The RU-SM16A uses bright LEDs for good visibility. Each channel input has a label area for identification of the source or function being metered.
Features:
- Precision Audio Level Metering
- Digital 16 LED String Display Indication
- Two Mono Meters or Stereo Metering
- Line-Level, Speaker-Level or 25/70/100 V Audio Input
- Selectable Fixed or Variable Calibration
- Individual Channel Calibration Controls
- Selectable Peak or Average Metering
- Peak-Hold Display for +10, +14, +18 dB
Specifications
Inputs (2):
Line level or Amplified speaker level
Input Impedance:
> 40 kΩ balanced or unbalanced
0 dB Calibration:
Fixed or Variable (switch-selectable)
Fixed Input Level:
+4 dBu (+4 switch settings, for 0 dB reading)
25 V* (25 V switch settings, for 0 dB reading)
70 V* (70 V switch settings, for 0 dB reading)
100 V* (100 V switch settings, for 0 dB reading)
Variable Input Level Range:
-24 dBu to +12 dBu (+4 switch settings, for 0 dB reading)
2 V to 90 V* (25 V switch settings, for 0 dB reading)
4 V to 90 V* (70 V switch settings, for 0 dB reading)
5 V to 100 V* (100 V switch settings, for 0 dB reading)
*Constant-voltage or low-impedance (4 Ohms, 8 Ohms) amplifier output
Metering Freq. Response:
20 Hz to 20 kHz
Indicators:
SIG, -20, -15, -12, -9, -6, -3, -2, -1, 0, +1.5, +3, +6, +10, +14, +18
(+10, +14, +18 are PEAK HOLD indicators only)
Metering Response:
Each channel individually selectable PEAK or AVG (switch-selectable)
Rise Time (10% to 90%):
Rise Time (0% to 100%):
Fall Time (90% to 10%):
Fall Time (100% to 0%):
Peak Mode Average Mode
50 us 130 ms
60 us 300 ms (VU Characteristic)
65 ms 185 ms
100 ms 300 ms (VU Characteristic)
Ambient Operating Environment:
0° C to 55° C
Power Requirement:
GROUND-REFERENCED, 24 Vdc @ 250 mA
Package Type:
Cardboard Box
Package Dimensions:
6 x 6 x 2.625 in.
Shipping Weight:
1.205 lbs.
Tariff code:
9030.33.3800
RDL Three-Year Limited Warranty
Installation of these products by the Purchaser shall constitute Purchaser’s acknowledgement and acceptance of the terms and
conditions for sale and of this warranty, and shall constitute the Purchaser’s determination of the suitability of this product for the
Purchaser’s intended application. Radio Design Labs, Inc., also referred to as RDL®, warrants to the Purchaser that products
manufactured by RDL are free from defects in material and workmanship. This warranty applies to the period of three years from the date
of shipment, except for component parts or products purchased from other sources and supplied by RDL. Such component parts or
products bear only the warranty of the manufacturer thereof in effect at the time of shipment to the Purchaser. RDL will, without charge,
and after written notice has been received and acknowledged by RDL, repair an RDL product if proved to be defective according to the
usage of the trade, when such equipment is received by RDL at the location it designates with shipment costs prepaid by the Purchaser.
RDL shall not be liable for any expense whether for repairs, replacements, material, service, or otherwise, incurred by the Purchaser or
modifications made by the Purchaser to the product. No equipment shall be deemed defective if it shall fail to operate in a normal or
proper manner due to exposure to excessive moisture in the atmosphere, excessive temperature extremes, improper environmental
cleanliness, or any other environment not consistent with the principles of good engineering practice. In no event shall RDL have any
liability for consequential damage or expense directly or indirectly arising from the use of the products, or any inability to use it either
separately or in combination with other equipment or materials, or from any other cause, whether used in accordance with instructions or
not. This warranty is void if equipment is altered in any way by other than RDL. RDL products are NOT intended for use in life support
appliances, devices, or systems. Use of RDL products in such applications is done solely at the liability of the reseller/installer and/or end
user. RDL reserves the right to change design parameters and specifications at any time without notice. The performance measurements
reflect the products at the time of printing. This warranty is in lieu of all others, either expressed or implied. No representative is authorized
to assume for RDL any other liability in connection with RDL products.