Overview
RVR-BLUES 50NV, 50 Watt Ultra Compact Transmitter
- PRIMARY APPLICATION: high-quality transmission at a very attractive price, ideal for repeater stations or like exciter of ultracompact systems. Adjustable power output from 10 to 100 %.
- HARDWARE FEATURES: ultra-compact and ultra-light (only 6Kg.), stainless steel chassis, in 1 rack unit only.
- USER-FRIENDLY FEATURES: universal 80-260 V multi-voltage power supply enables operation without preselect voltage. Pressure encoder provides great accessibility for user/device interaction, resulting in extreme of use. Configuration software offers an simple, intuitive interface.
- RELIABILITY/CONTINUITY: the APC (Automatic Power Control) and Foldback protection ensures enhanced business continuity under any operating conditions.
- AUDIO PERFORMANCE: low distortion and intermodulation values and a high noise/signal ratio with an AES/EBU input (optional) automatically managed in exchange.
- OPERATING EFFICIENCY: incorporate a PFC (Power Factor Corrector) power supply, that provides the utmost efficiency for enhanced energy saving and environmental protection, which ensure high efficiency across the bandwidth.
- EASE OF MAINTENANCE: advanced module engineering ensures extreme of access and simple maintenance.
- INTERFACE CONTROL: total control thanks to microprocessor easily programmed from menu with all key parameters displayed on LCD.
- INTERFACE CONTROL: total control thanks to microprocessor easily programmed from menu with all key parameters displayed on LCD.
- INPUT/OUTPUT INTERFACE: built-in high-performance stereo coder, L&R, Mono, MPX and auxiliary inputs for SCA / RDS signals and AES/EBU digital.
- REGULATORY COMPLIANCE: state-of-the-art technology in full compliance with EC, FCC and CCIR standards.
Specifications
BLUES50NV | ||||
Parameters | U.M. | Value | Notes | |
GENERALS | ||||
Frequency range | MHz | 87,5 ÷ 108 | ||
Rated output power | W | 50 | Continuously adjustable from 10 to 100% | |
Modulation type | F3E Direct carrier frequency | |||
Operational mode | Mono, Stereo, Multiplex | |||
Working temperature | °C | -5 to +50 | ||
Working humidity | % | 95 | No condensing | |
Working altitude | mt | Up to 2000 * | * With adequate air evacuation system in site | |
Frequency setting | kHz | 10 | Steps | |
Frequency stability | Temperature range from -5°C to 50°C | ppm | ±1 | |
Modulation capability | Refered @ 0dBu for 75kHz | kHz | 150 Stereo, 180 Mono/MPX | Meets or exceeds all FCC and CCIR rules |
Pre-emphasis | µS | 0, 50 (CCIR), 75 (FCC) | Selectable | |
POWER REQUIREMENTS | ||||
AC Power input | AC Supply Voltage | VAC | 80 ÷ 260 | |
AC Apparent Power Consumption | VA | 200 | ||
Active Power Consumption | W | 100 | ||
Power Factor | 0,5 | |||
Overall Efficiency | % | Typical 50 | ||
Connector | VDE IEC Standard | |||
MECHANICAL DIMENSIONS | ||||
Phisical dimensions | Front panel width | mm / inch | 483 / 19 | EIA rack |
Front panel height | mm / inch | 44 / 3 1/2 | 1HE | |
Overall depth | mm | 394 | ||
Chassis depth | mm | 372 | ||
Weight | kg | About 5,5 | ||
Cooling | Forced, with internal fan | |||
Acoustic noise | dBA | < 58 | ||
AUDIO INPUTS | ||||
Left / Mono | Connector | XLR F | ||
Type | Balanced | |||
Impedance | Ohm | 10 k or 600 | ||
Input Level /Adjust | dBu | -13 to +13 | Continuosly adjustable | |
Right | Connector | XLR F | ||
Type | Balanced | |||
Impedance | Ohm | 10 k or 600 | ||
Input Level | dBu | -13 to +13 | Continuosly adjustable | |
MPX | Connector | BNC | ||
Type | Unbalanced | |||
Impedance | Ohm | 10 k or 50 | ||
Input Level /Adjust | dBu | -13 to +13 | For 75 KHz FM, adjustable | |
SCA/RDS | Connector | 2xBNC | ||
Type | Unbalanced | |||
Impedance | Ohm | 10 k | ||
Subcarier Level @ 0 dBu | dB | -17 to -40 | For 7,5 KHz FM, adjustable | |
AES/EBU (optional) | Connector | XLR F | ||
Type | Balanced | |||
Impedance | Ohm | 110 | ||
Input Level /Adjust | dBfs | 0 to -10 | For 7,5 KHz FM, adjustable | |
TOS/Link (optional) |
||||
OUTPUTS | ||||
RF Output | Connector | N type | ||
Impedance | Ohm | 50 | ||
RF Monitor | Connector | BNC | ||
Impedance | Ohm | 50 | ||
Output Level | dB | Approx. -30 | ||
Pilot output | Connector | BNC | ||
Load Impedance | Ohm | >5 K | ||
Output Level | Vpp | 1 | Sinusoidal | |
FUSES | ||||
On mains | 1 External fuse F 6,3 T - 5x20 mm | |||
On services | X | |||
On PA Supply | X | |||
On driver supply | X |