Overview
Tripp-Lite SMART1000RM2U, SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, 2U Rack/Tower, Network Card Options, LCD, USB, DB9, 6 Outlets
Protects connected mission-critical equipment against damage, downtime and data loss due to blackouts, brownouts, power surges and line noise. Ideal solution for data centers, VoIP systems and network closets.
Protects Mission-Critical Rack-Mounted Equipment
- Provides fully regulated sine wave AC output for servers, network storage devices and telecom hardware
- Audible alarm signals loss of utility power, overload, low battery and fault conditions
- 6 NEMA 5-15R outlets
- 10-ft. (3.05 m) power cord with 120V NEMA 5-15P input
- 570-joule surge suppression rating
- Supports half load up to 15 min. and full load up to 5.3 min.
- Internal batteries designed for hot-swap field replacement
- 95% line-power efficiency rating saves money in energy costs
- 2 load banks, each with 2 outlets controllable remotely to reboot equipment or shed nonessential loads
Specifications / Documents
INPUT
- Rated input current (Maximum Load): 9.2A
- Nominal Input Voltage(s) Supported: 120V AC
- UPS Input Connection Type:: 5-15P
- Input Circuit Breakers: 15A
- UPS Input Cord Length (ft.): 10
- Recommended Electrical Service: 15A 120V
- Input Phase: Single-Phase
OUTPUT
- Output Volt Amp Capacity (VA): 1000
- Output Capacity (kVA): 1.0
- Output Watt Capacity (Watts): 800
- Power Factor: 0.8
- Nominal Voltage Details: 120v nominal output in battery mode
- Frequency Compatibility: 60 Hz
- Output Voltage Regulation (Line Mode): -21%, +8%
- Output Voltage Regulation (Battery Mode): +/- 5%
- Load Management Receptacles: Two switchable two-outlet 5-15R load banks
- Output AC Waveform (AC Mode): Sine wave
- Output AC Waveform (Battery Mode): Pure Sine wave
- Nominal Output Voltage(s) Supported: 110V; 115V; 120V
- Output Receptacles: (6) 5-15R
- Individually Controllable Load Banks: Yes
BATTERY
- Battery Type: Valve Regulated Lead Acid (VRLA)
- Full Load Runtime (min.): 5.3 min. (800w)
- Half Load Runtime (min.): 15 min. (400w)
- Expandable Runtime: No
- DC System Voltage (VDC): 24
- Battery Recharge Rate (Included Batteries): Less than 4 hours from 10% to 90% (typical, full load discharge)
- Battery Access: Front panel battery access door
- Internal UPS Replacement Battery Cartridge: Current version uses RBC24V-LCD ; Prior versions used RBC92-2U ; Check the label inside the battery door to verify the appropriate replacement battery part number
- Battery Replacement Description: Hot-swappable, user replaceable batteries
VOLTAGE REGULATION
- Voltage Regulation Description: Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 83 to 147
- Overvoltage Correction: Input voltages between 128 and 147 are reduced by 12%
- Undervoltage Correction: Input voltages between 83 and 107 are boosted by 14%
2-year warranty, 3 year with registration