Overview
Tripp-Lite SMART1500RM2U SmartPro 120V 1.5kVA 1.35kW Line-Interactive Sine Wave UPS, 2U, Network Card Options, LCD, USB, DB9, 8 Outlets
Protects Mission-Critical Rack-Mounted Equipment
- Provides fully regulated sine wave AC output for servers, network storage devices and telecom hardware
- Audible alarm signals loss of utility power, overload, low battery and fault conditions
- 8 NEMA 5-15R outlets
- 10-ft. (3.05 m) power cord with 120V NEMA 5-15P input
- 0.9 power factor rating
- 570-joule surge suppression rating
Reliable Battery Backup
- Supports half load up to 13 min. and full load up to 4.5 min.
- Internal batteries designed for hot-swap field replacement
- 95% line-power efficiency rating saves money in energy costs
2 Load Banks with Switchable Outlets
- Can control 4 outlets remotely to reboot equipment or shed nonessential loads
Specifications
INPUT
Rated input current (Maximum Load) |
12A |
Nominal Input Voltage(s) Supported |
120V AC |
UPS Input Connection Type |
5-15P |
Input Circuit Breakers |
15A |
UPS Input Cord Length (ft.) |
10 |
Recommended Electrical Service |
15A 120V |
Input Phase |
Single-Phase |
OUTPUT
Output Volt Amp Capacity (VA) |
1500 |
Output Capacity (kVA) |
1.5 |
Output Watt Capacity (Watts) |
1350 |
Output kW Capacity (kW) |
1.35 |
Power Factor |
0.9 |
Nominal Voltage Details |
120v nominal output in battery mode |
Frequency Compatibility |
60 Hz |
Output Voltage Regulation (Line Mode) |
-21%, +8% |
Output Voltage Regulation (Battery Mode) |
+/- 5% |
Load Management Receptacles |
Two switchable two-outlet 5-15R load banks |
Output AC Waveform (AC Mode) |
Sine wave |
Output AC Waveform (Battery Mode) |
Pure Sine wave |
Nominal Output Voltage(s) Supported |
110V; 115V; 120V |
Output Receptacles |
(8) 5-15R |
Individually Controllable Load Banks |
Yes |
BATTERY
Battery Type |
Valve Regulated Lead Acid (VRLA) |
Full Load Runtime (min.) |
4.5 min. (1350w) |
Half Load Runtime (min.) |
13 min. (675w) |
Expandable Runtime |
No |
DC System Voltage (VDC) |
36 |
Battery Recharge Rate (Included Batteries) |
Less than 4.5 hours from 10% to 90% (typical, full load discharge) |
Battery Access |
Front panel battery access door |
Internal UPS Replacement Battery Cartridge |
RBC93-2U |
Battery Replacement Description |
Hot-swappable, user replaceable batteries |
VOLTAGE REGULATION
Voltage Regulation Description |
Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 83 to 147 |
Overvoltage Correction |
Input voltages between 128 and 147 are reduced by 12% |
Undervoltage Correction |
Input voltages between 83 and 107 are boosted by 14% |
USER INTERFACE, ALERTS & CONTROLS
Front Panel LCD Display |
Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data, plus configuration of voltage, operating mode, alarm function and a variety of additional options (see manual for detailed LCD configuration and monitoring options) |
Switches |
3 pushbutton switches control OFF / ON power status, MODE selection and MUTE / ENTER control functions |
Alarm Cancel Operation |
Power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option available |
Audible Alarm |
Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions |
SURGE / NOISE SUPPRESSION
UPS AC Suppression Joule Rating |
570 |
UPS AC Suppression Response Time |
Instantaneous |
EMI / RFI AC Noise Suppression |
Yes |
To Expand, Right Click and Open Link in New Tab