Overview
Tripp-Lite SMART1500RM2U SmartPro 120V 1.5kVA 1.35kW Line-Interactive Sine Wave UPS, 2U, Network Card Options, LCD, USB, DB9, 8 Outlets
Protects Mission-Critical Rack-Mounted Equipment
- Provides fully regulated sine wave AC output for servers, network storage devices and telecom hardware
- Audible alarm signals loss of utility power, overload, low battery and fault conditions
- 8 NEMA 5-15R outlets
- 10-ft. (3.05 m) power cord with 120V NEMA 5-15P input
- 0.9 power factor rating
- 570-joule surge suppression rating
Reliable Battery Backup
- Supports half load up to 13 min. and full load up to 4.5 min.
- Internal batteries designed for hot-swap field replacement
- 95% line-power efficiency rating saves money in energy costs
2 Load Banks with Switchable Outlets
- Can control 4 outlets remotely to reboot equipment or shed nonessential loads
Specifications / Documents
INPUT
- Rated input current (Maximum Load): 12A
- Nominal Input Voltage(s) Supported: 120V AC
- UPS Input Connection Type: 5-15P
- Input Circuit Breakers: 15A
- UPS Input Cord Length (ft.): 10
- Recommended Electrical Service: 15A 120V
- Input Phase: Single-Phase
OUTPUT
- Output Volt Amp Capacity (VA): 1500
- Output Capacity (kVA): 1.5
- Output Watt Capacity (Watts): 1350
- Output kW Capacity (kW): 1.35
- Power Factor: 0.9
- Nominal Voltage Details: 120v nominal output in battery mode
- Frequency Compatibility: 60 Hz
- Output Voltage Regulation (Line Mode): -21%, +8%
- Output Voltage Regulation (Battery Mode): +/- 5%
- Load Management Receptacles: Two switchable two-outlet 5-15R load banks
- Output AC Waveform (AC Mode): Sine wave
- Output AC Waveform (Battery Mode): Pure Sine wave
- Nominal Output Voltage(s) Supported: 110V; 115V; 120V
- Output Receptacles: (8) 5-15R
- Individually Controllable Load Banks: Yes
BATTERY
- Battery Type: Valve Regulated Lead Acid (VRLA)
- Full Load Runtime (min.): 4.5 min. (1350w)
- Half Load Runtime (min.): 13 min. (675w)
- Expandable Runtime: No
- DC System Voltage (VDC): 36
- Battery Recharge Rate (Included Batteries): Less than 4.5 hours from 10% to 90% (typical, full load discharge)
- Battery Access: Front panel battery access door
- Internal UPS Replacement Battery Cartridge: RBC93-2U
- Battery Replacement Description: Hot-swappable, user replaceable batteries
VOLTAGE REGULATION
- Voltage Regulation Description: Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 83 to 147
- Overvoltage Correction: Input voltage between 128 and 147 are reduced by 12%
- Undervoltage Correction: Input voltages between 83 and 107 are boosted by 14%
USER INTERFACE, ALERTS & CONTROLS
- Front Panel LCD Display: Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data, plus configuration of voltage, operating mode, alarm function and a variety of additional options (see manual for detailed LCD configuration and monitoring options)
- Switches: 3 pushbutton switches control OFF / ON power status, MODE selection and MUTE / ENTER control functions
- Alarm Cancel Operation: Power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option available
- Audible Alarm Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions
SURGE / NOISE SUPPRESSION
- UPS AC Suppression Joule Rating: 570
- UPS AC Suppression Response Time: Instantaneous
- EMI / RFI AC Noise Suppression: Yes