Kintronic LAB9.50 Automatic Dehydrator

$5,505.00 - $7,230.00
Write a Review
SKU:
KIN-LAB950 SERIES
Availability:
Ships from Manufacturer, Contact us for Pricing and Availability

Overview

Kintronic LAB9.50 Automatic Dehydrator

The LAB series dehydrators are programmed to maintain a single target pressure level. The unit is comprised of two alternating diaphragm pumps that are driven to operate below their maximum flow rate.
While the first chamber is active, the desiccant in the second chamber is regenerated through heating and back-washing with a small reverse dry air flow. The pumps are controlled electronically by Pulse Width Modulation (PWM), supplying a flow rate equivalent to the real time leakage rate. With the PWM control, there is an imperceptible vibration of the diaphragm pump. Maintaining the target pressure level eliminates the need for a pressure regulator, which means no pressure losses and an overall better response to flow regulation. Through this design, the dehydrator avoids the stress of continuously switching on at maximum speed and then switching off. Additionally, there are no mechanical parts in movement (except the diaphragm pumps) and no solenoid valves, thus reducing overall wear. The result is an increased MTBF and overall lifetime of the unit, as well as reduced noise and power consumption.

Optional Features:
 Remote control through SNMP protocol and HTTP interface by a 10/100 Mbit Ethernet interface
 Digital flowmeter that displays real-time leakage rate on front LCD display panel

Pressurization Chart:

  • 7/8″ Coax: up to 77,100 ft (23500m)
  • 1-5/8″ Coax: up to 24,278 ft (7400m)
  • 2-1/4″ Coax: up to 16,404 ft (5000m)
  • 3-1/8″ Coax: up to 7,218 ft (2200m)
  • 6-1/8″ Coax: up to 2,034 ft (620m)

 

Specifications

  • Maximum Flow Rate: 678 SCFD (800 l/h) 
  • Output pressure: Factory set at 4.5 PSI (programmable from 1.5 – 8.5 PSI)
  • Output Air Dew Point: Better than -40 o F at 68 o F (20 o C) ambient temperature and 80% Relative Humidity
  • Safety Valve: Factory set at 10 PSI +/-10%
  • Dessicant Regeneration: Automatic by heating
  • Regeneration Phase Interval: Adaptive according to plant leakages
  • MTBF: Higher than 165,000 h, according to MIL HDBK 217F at Ground Base conditions, 77F ambient temperature, 50% flow rate
  • Outlets: 8 outlets, each with ON/OFF valve
  • Outlets Fitting" 3/8” (9.5 mm) diameter
  • Mounting: Wall and floor, 19” and ETSI N3 racks Wall, 19” and ETSI N3 racks
  • Weight: 35 lbs (9 kg)
  • Power Supply: AC - 110-240 V, 50/60 Hz, OR DC - 48/60 V
  • Local Alarms: Low/high pressure; high humidity; system failures
  • Remote Alarms: All alarms are remotely signaled by SPDT Relay
  • Low Pressure Alarm: Factory set at 1.5 PSI; programmable from 0.5
  • High Pressure Alarm: Factory set at 9 PSI; programmable up to 10 PSI 
  • High Humidity Alarm: Set at 10% of relative humidity +/- 2%
  • LED Indications: Power on; Alarms
  • Optional Remote Monitoring: Web browser and SNMP
  • Standard Measures: Air pressure; hour meter (OPTION: air flow by digital flow meter)