Moseley Starlink Transfer Panel TP-128-HP
The TP-128-HP Transfer Panel is the control point of a fully redundant STL. Redundancy can protect from lost revenue and costly engineering time caused by a microwave radio outage.
- System
- Type: Latching Transfer Switch (standby TX switched into 50-ohm power termination)
- Frequency Range: 0-18 GHz (with internal relay)
- Load Power: 10 Watts (< 3 GHz); 5 Watts (> 3 GHz)
- Internal RF Relay
- Type: Make before Break Transfer Switch
- Switching Time: 15 ms, max.
- External RF Relay
- Supply Voltage: 12V or 24/28V (model dependent)
- Current Capability: 1.0A, max.
- Dry Relay Contacts: 5.0A, 50V, max.
- Status Inputs: 2 TTL or contact closure
- Radio Interfaces:
- RF: 2 Radio, 1 Antenna, 1 Load SMA Female
- Control: DB-9M and RJ-45
- Control
- Network Management: SNMP, Proprietary Web GUI, CLI
- LAN.NMS Connector: 10/100Base-T RJ-45 Female
- Serial: 115,200 b/s DB-9M
- MIMIC Port: 4 TTL Output 2 TTL or contact closure Input 2.5mm Terminal Block Over Heat Sinks
- Power:
- DC Power: -48 Vdc ±10%, <12.5 W
- AC Power: 100-240 Vac, 47-63 Hz, <0.2 A
- Size: 17.5w x 1.75h x 11.5d inches
- Weight: 10 lbs (4.5 Kg)