Overview
The RU-SQ6A is the ideal choice in installations where sequential ON and sequential OFF functions are desired. Control and output connections are made on the rear panel through clearly identified detachable terminal blocks.
Two types of outputs are provided for each of the 6 sequential steps. One type is an open collector capable of switching loads of 50mA. The other type is an SPST dry contact closure which may be used to control a variety of equipment. A single-turn front-panel TIMING INTERVAL control adjusts the time delay between channels from 1 to 10 seconds. Front-panel LEDs show when each output channel turns on and off. An internal microcontroller insures reliable, accurate timing.
The up or down sequence is user-controlled by a front-panel pushbutton switch unless the module is set for remote operation. A rear-panel switch set by the installer selects either front-panel or remote control activation. LEDs indicate whether the front-panel SEQUENCE CONTROL switch or the remote terminals are active. Grounding the rear-panel ACTIVATE terminals or turning on the front-panel SEQUENCE CONTROL switch causes an UP REQUEST that starts the RU SQ6A outputs to turn on sequentially. The outputs remain active until the UP REQUEST is cancelled by turning off the front-panel or remote control switch, causing the outputs to turn off in reverse sequence. If the ACTIVATE terminal is permanently grounded with the module set for remote control, the RU-SQ6A outputs will turn on sequentially when power is applied to the module; all outputs will turn off simultaneously when power is removed from the RU-SQ6A. The UP REQUEST LED is illuminated when an UP sequence is requested. When the sequence is complete, the COMPLETE LED indicates the Sure-Lok™ supervisory circuit is actively latching the outputs active until the user de-activates the sequence.
Features:
- Control of Sequential Power-Up or Events
- Adjustable Up/Down Time Interval
- Open-collector Outputs
- Relay Contact Closures
- Up to Six Sequential Events
- Sure-Lok™ Output Supervision
Specifications
Control Input:
External closure < 2.5 mA @ 24 Vdc
Interval Between Outputs:
1 to 10 seconds nominal, front-panel adjustable
Indicators (10):
Red LEDs indicating channel 'on' condition (6)
Green LED indicating UP REQUEST
Green LED indicating sequence COMPLETE
Red / Green LEDs indicating Remote or Front-Panel Activation
24 Vdc Output:
1.1 A maximum, 100 mA less than power supply current
Open Collector (6):
200 mA surge; 50 mA continuous; 200 mA maximum
Relay Outputs (6): SPST (closed when active)
Maximum Switching Power:60 W (220 Vdc, 125 Vac, 2A)
Maximum Switching Voltage:220 Vdc, 250 Vac
Maximum Switching Current:2 A
Maximum Carrying Current:3 A
Ambient Operating Environment:0° C to 50° C
Power Requirement:
24 Vdc @ 100 mA (plus total load current connected to 24 Vdc output)
Dimensions:
Height: 1.7 in. 4.3 cm; Length: 5.8 in. 15.0 cm; Depth: 3.45 in. 8.8 cm
Package Type:
Cardboard Box
Package Dimensions:
4.375 x 7 x 2.25 in.
RDL Three-Year Limited Warranty
Installation of these products by the Purchaser shall constitute Purchaser’s acknowledgement and acceptance of the terms and
conditions for sale and of this warranty, and shall constitute the Purchaser’s determination of the suitability of this product for the
Purchaser’s intended application. Radio Design Labs, Inc., also referred to as RDL®, warrants to the Purchaser that products
manufactured by RDL are free from defects in material and workmanship. This warranty applies to the period of three years from the date
of shipment, except for component parts or products purchased from other sources and supplied by RDL. Such component parts or
products bear only the warranty of the manufacturer thereof in effect at the time of shipment to the Purchaser. RDL will, without charge,
and after written notice has been received and acknowledged by RDL, repair an RDL product if proved to be defective according to the
usage of the trade, when such equipment is received by RDL at the location it designates with shipment costs prepaid by the Purchaser.
RDL shall not be liable for any expense whether for repairs, replacements, material, service, or otherwise, incurred by the Purchaser or
modifications made by the Purchaser to the product. No equipment shall be deemed defective if it shall fail to operate in a normal or
proper manner due to exposure to excessive moisture in the atmosphere, excessive temperature extremes, improper environmental
cleanliness, or any other environment not consistent with the principles of good engineering practice. In no event shall RDL have any
liability for consequential damage or expense directly or indirectly arising from the use of the products, or any inability to use it either
separately or in combination with other equipment or materials, or from any other cause, whether used in accordance with instructions or
not. This warranty is void if equipment is altered in any way by other than RDL. RDL products are NOT intended for use in life support
appliances, devices, or systems. Use of RDL products in such applications is done solely at the liability of the reseller/installer and/or end
user. RDL reserves the right to change design parameters and specifications at any time without notice. The performance measurements
reflect the products at the time of printing. This warranty is in lieu of all others, either expressed or implied. No representative is authorized
to assume for RDL any other liability in connection with RDL products.