Overview
Trip-Lite SMART3000RMXL2U SmartPro 120V 3kVA 2.88kW Line-Interactive Sine Wave UPS, 2U, Extended Run, Network Card Options, LCD, USB, DB9
Tripp Lite SmartPro Line Interactive UPS with enhanced LCD interface offers network-grade power protection for critical server, network and telecommunications equipment. Line Interactive Uninterruptible Power Supply (UPS) with built-in Auto-Voltage Regulation (AVR) actively corrects brownouts and overvoltages back to usable levels while maintaining a full battery charge in case of power failure. Tripp Lite's unique configuration excels in exceptionally poor-power environments with two separate levels of voltage boost to correct both slight undervoltages and severe brownout conditions. Interactive LCD interface reports UPS operating mode, detailed UPS and site-power data, plus enables a variety of UPS setup and configuration options. Super-fast switchover from line to battery power occurs within milliseconds to maintain operation of connected equipment without interruption or reboot. 96% line-mode efficiency offers reduced heat emissions and operating costs. Network management interfaces support communications via USB, RS-232 and optional Network Management Card option. HID-compliant USB port enables integration with built-in power management and auto shutdown features of Windows and Mac OS X. Network communications ports enable detailed monitoring of equipment load levels, self-test data and utility power conditions. PowerAlert UPS monitoring software is available via free download. Switched output load banks enable scheduled and real-time remote reboot and load shedding of select outlets. Emergency Power Off (EPO) interface. LCD display panel easily rotates for viewing in rackmount or tower configurations. Audible alarm with push-button momentary alarm-cancel and silent-mode configuration options. Programmable self-test. Field-replaceable, hot-swappable battery modules.
- 3kVA / 3000VA / 2880W line interactive 2U rack/tower UPS, Sine Wave
- Extended runtime options up to 2880W, 0.96 Power Factor, 4 post mounting kit
- USB, RS232, EPO and slot for network management card options
- 120V NEMA L5-30P input, 8 NEMA 5-15/20R & 1 L5-30R outlets
- To use the Auto Probe feature, this product requires a WEBCARDLX network interface (sold separately) running LX firmware update 15.5.2 or later
Specifications / Documents
INPUT
- Rated input current (Maximum Load): 24A
- Nominal Input Voltage(s) Supported: 120V AC
- UPS Input Connection Type: L5-30P
- UPS Input Cord Length (ft.): 10
- Recommended Electrical Service: 30A 120V
- Input Phase: Single-Phase
OUTPUT
- Output Volt Amp Capacity (VA): 3000
- Output Capacity (kVA): 3.00
- Output Watt Capacity (Watts): 2880
- Output kW Capacity (kW): 2.88
- Power Factor: .96
- Nominal Voltage Details: 120v nominal output in battery mode
- Frequency Compatibility: 60 Hz
- Output Voltage Regulation (Line Mode): +6%, -14%
- Output Voltage Regulation (Battery Mode): +/-5%
- Load Management Receptacles: Two switchable single outlet 5-15/20R load banks
- Output Circuit Breakers: Two 20A output breakers protect 4 5-15/20R outlets each
- Output AC Waveform (AC Mode): Pure Sine wave
- Output AC Waveform (Battery Mode): Pure Sine wave
- Nominal Output Voltage(s) Supported: 110V; 115V; 120V
- Output Receptacles:
- (8) 5-15/20R
- (1) L5-30R
- Individually Controllable Load Banks: Yes
BATTERY
- Battery Type: Valve Regulated Lead Acid (VRLA)
- Full Load Runtime (min.): 3 min. (2880w)
- Half Load Runtime (min.): 10 min. (1440w)
- Expandable Battery Runtime: Extended runtime supported via optional external battery packs
- Expandable Runtime: Yes
- External Battery Pack Compatibility:
- BP48V24-2U (limit 1)
- BP48V60RT-3U (multi-pack compatible)
- BP48V27-2US (multi-pack compatible)
- DC System Voltage (VDC): 48
- Battery Recharge Rate (Included Batteries): Less than 5 hours from 10 to 90% (typical, full load discharge)
- Battery Access: Front panel battery access door
- Internal UPS Replacement Battery Cartridge: RBC58-2U
- Battery Replacement Description: Hot-swappable, replaceable batterie
VOLTAGE REGULATION
- Voltage Regulation Description: Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 83 to 145
- Overvoltage Correction: Input voltages between 127 and 145 are reduced by 12%
- Undervoltage Correction: Input voltages between 108 and 96 are boosted by 12%
- Severe Undervoltage Correction: Input voltages between 83 and 95 are boosted by 24%
USER INTERFACE, ALERTS & CONTROLS
- Front Panel LCD Display: Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data, plus configuration of voltage, operating mode, alarm function and a variety of additional options (see manual for detailed LCD configuration and monitoring options)
- Switches: 3 pushbutton switches control OFF / ON power status, MODE selection and MUTE / ENTER control functions
- Alarm Cancel Operation: Power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option available
- Audible Alarm: Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions
SURGE / NOISE SUPPRESSION
- UPS AC Suppression Joule Rating: 570
- EMI / RFI AC Noise Suppression: Yes
- AC Suppression Response Time: Instantaneous