RDL ST-LCR3 Dual Alternate Pulse Logic Controlled Relay

MSRP: $235.75
$176.82
Write a Review
SKU:
RDL-STLCR3
Availability:
Normally Ships From Manufacturer, Contact us for Pricing and Availability
Type:
Relay

Overview

The ST-LCR3 is ideally suited to applications where momentary pulses are needed from a single control signal. The module provides a momentary pulse when a logic signal at its input first becomes active. A separate momentary pulse is provided when the logic signal at the module input becomes inactive.

Two logic inputs are available on the ST-LCR3. Either of these inputs may be used. Terminal 1 is internally pulled high to +5 Vdc. This input becomes active when an external closure or open-collector pulls the terminal to ground. The external switching device does not need to pull the terminal high, however the terminal may be pulled high with any voltage from +3.3 Vdc to +24 Vdc without any risk of damage to the ST-LCR3 input. Terminal 3 is internally pulled to ground. This input becomes active when an external closure or logic device applies a positive voltage from +3.3 Vdc to + 24 Vdc.

When the input being used first becomes active the START PULSE output from the module is triggered. When the input first becomes inactive (after first being active) the END PULSE output from the module is triggered. Both the start and end pulses have a nominal duration of 250 ms.

Each pulse output provides both an open-collector SLAVE terminal and relay contacts. The SLAVE terminal may be used to control other RDL modules and a variety of other equipment. The relay contacts may be used to control modules or equipment that do not operate from open-collector control.

Features:

  • Pulse at the Start of a Logic Signal
  • Pulse at the End of a Logic Signal
  • Relay Contact and Open-Collector Pulse
  • Active High or Active Low Inputs
  • Input Control Voltage From 3.3 to 24 Vdc
  • Control from Switch, Pushbutton, or Logic Circuits

Specifications

Inputs (2):
Logic High or Logic Low (Low = ground, High = 3.3 Vdc to 24 Vdc)
 
Outputs (2):
Open collector @ 25 mA suitable to drive indicators or slave LCRs.
 
Switching Contacts:
Single Pole Relay Contacts (2)
 
Maximum Switching Power:
60 W (220 Vdc, 125 Vac, 2 A)
 
Ambient Operating Environment
0° C to 55° C
 
Power Requirement:
GROUND-REFERENCED, 24 Vdc @ 100 mA (assuming 20 mA max load at SLAVE output)
 
Package Type:
Cardboard Box
 
Package Dimensions:
2 x 2 x 4 in.
 
Shipping Weight:
0.2 lbs.
 
 

 

RDL Three-Year Limited Warranty Installation of these products by the Purchaser shall constitute Purchaser’s acknowledgement and acceptance of the terms and conditions for sale and of this warranty, and shall constitute the Purchaser’s determination of the suitability of this product for the Purchaser’s intended application. Radio Design Labs, Inc., also referred to as RDL®, warrants to the Purchaser that products manufactured by RDL are free from defects in material and workmanship. This warranty applies to the period of three years from the date of shipment, except for component parts or products purchased from other sources and supplied by RDL. Such component parts or products bear only the warranty of the manufacturer thereof in effect at the time of shipment to the Purchaser. RDL will, without charge, and after written notice has been received and acknowledged by RDL, repair an RDL product if proved to be defective according to the usage of the trade, when such equipment is received by RDL at the location it designates with shipment costs prepaid by the Purchaser. RDL shall not be liable for any expense whether for repairs, replacements, material, service, or otherwise, incurred by the Purchaser or modifications made by the Purchaser to the product. No equipment shall be deemed defective if it shall fail to operate in a normal or proper manner due to exposure to excessive moisture in the atmosphere, excessive temperature extremes, improper environmental cleanliness, or any other environment not consistent with the principles of good engineering practice. In no event shall RDL have any liability for consequential damage or expense directly or indirectly arising from the use of the products, or any inability to use it either separately or in combination with other equipment or materials, or from any other cause, whether used in accordance with instructions or not. This warranty is void if equipment is altered in any way by other than RDL. RDL products are NOT intended for use in life support appliances, devices, or systems. Use of RDL products in such applications is done solely at the liability of the reseller/installer and/or end user. RDL reserves the right to change design parameters and specifications at any time without notice. The performance measurements reflect the products at the time of printing. This warranty is in lieu of all others, either expressed or implied. No representative is authorized to assume for RDL any other liability in connection with RDL products.